Level:
Correct: 0
Incorrect: 0
Marks: 0/0

Microscopy

Practise 11 exam-style questions on Microscopy for AQA GCSE Combined Science (Biology Paper 1). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 11 questions
  • 1–6 marks each
  • Instant marking
  • No sign-up needed
11 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

2 marks

A chloroplast is 5 μm long. A photograph is taken of it through a light microscope at a magnification of ×1500.

Calculate the length of the chloroplast in the photograph in millimetres.

Model answer

Size of image = magnification × size of real object = 1500 × 5 = 7500 μm
7500 μm ÷ 1000 = 7.5 mm

Explanation

Rearrange the magnification equation to find the image size, then convert from μm to mm by dividing by 1000. The image must be larger than the real object, which is a useful check.

Mark scheme
  1. 1 mark

    image size = 1500 × 5 = 7500 (μm)

    an answer of 7.5 mm scores 2 marks

  2. 1 mark

    7.5 (mm)

    allow ecf from an incorrect image size in μm

Question 2

3 marks

A student viewed cheek cells with a light microscope. She used a ×10 eyepiece lens and a ×40 objective lens. The image of one cell was 12 mm wide.

Calculate the real width of the cell in micrometres (μm).

Model answer

Total magnification = 10 × 40 = ×400
Real width = size of image ÷ magnification = 12 ÷ 400 = 0.03 mm
0.03 mm × 1000 = 30 μm

Explanation

The total magnification of a light microscope is the eyepiece magnification multiplied by the objective magnification. Divide the image size by the magnification to get the real size, then convert mm to μm by multiplying by 1000.

Mark scheme
  1. 1 mark

    magnification = 10 × 40 = 400

    an answer of 30 μm scores 3 marks

  2. 1 mark

    real width = 12 ÷ 400 = 0.03 (mm)

    allow ecf from an incorrect magnification

  3. 1 mark

    30 (μm)

    allow ecf from an incorrect value in mm

Question 3

3 marks

An electron micrograph of a virus has a magnification of ×200 000. The image of the virus is 20 mm wide.

Calculate the real width of the virus in metres.
Give your answer in standard form.

Model answer

Real width = size of image ÷ magnification = 20 ÷ 200 000 = 0.0001 mm
0.0001 mm = 1 × 10⁻⁴ mm = 1 × 10⁻⁷ m

Explanation

Divide by the magnification to find the real size. There are 1000 mm in 1 m, so a length in mm is divided by 10³ to give metres: 10⁻⁴ mm = 10⁻⁷ m, which is 100 nm.

Mark scheme
  1. 1 mark

    real size = 20 ÷ 200 000

    an answer of 1 × 10⁻⁷ m scores 3 marks

  2. 1 mark

    = 0.0001 mm / 1 × 10⁻⁴ mm

    allow 0.1 μm or 100 nm; allow ecf

  3. 1 mark

    1 × 10⁻⁷ (m)

    allow ecf; standard form required for this mark

Question 4

4 marks

An electron micrograph shows a mitochondrion. On the micrograph, a scale bar labelled 1 μm is 25 mm long. The image of the mitochondrion is 50 mm long.

Use the scale bar to calculate the magnification of the micrograph and the real length of the mitochondrion.

Model answer

Scale bar: 25 mm = 25 000 μm
Magnification = size of image ÷ size of real object = 25 000 ÷ 1 = ×25 000
Real length = 50 mm ÷ 25 000 = 0.002 mm = 2 μm

Explanation

A scale bar has a known real length and a measurable image length, so it gives the magnification directly. Alternatively, the mitochondrion is twice the length of the scale bar, so its real length is 2 × 1 μm.

Mark scheme
  1. 1 mark

    25 mm = 25 000 μm

    an answer of ×25 000 and 2 μm scores 4 marks

  2. 1 mark

    magnification = 25 000 ÷ 1 = ×25 000

    allow 2.5 × 10⁴; allow ecf from an incorrect conversion

  3. 1 mark

    real length = 50 ÷ 25 000 = 0.002 mm

    allow 50 000 ÷ 25 000; allow the mitochondrion is 50 ÷ 25 = 2 times the scale bar; allow ecf

  4. 1 mark

    2 μm

    allow 0.002 mm or 2 × 10⁻⁶ m; allow ecf

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Revision notes

Microscopy

The big idea

Most cells are far too small to see with the naked eye, so biologists study them with microscopes. As microscopes have improved, biologists have seen more and more detail inside cells. You need to compare light and electron microscopes using magnification and resolution, and to use the magnification equation.

Magnification and resolution

  • Magnification is how many times bigger the image is than the real object.
  • Resolution (resolving power) is the ability to distinguish between two points that are close together, so it decides how much detail you can see. The smaller the distance between two points that can still be seen as separate, the higher the resolution.

Magnifying an image without improving its resolution just gives a bigger blur. This is why resolution, not magnification alone, limits what a microscope can show.

Light and electron microscopes

Light microscopeElectron microscope
UsesLightA beam of electrons
Maximum magnificationAbout × 1500 to × 2000Up to about × 2 000 000
ResolutionAbout 200 nmAs fine as about 0.2 nm
What it showsCells, nuclei, chloroplasts; mitochondria only as tiny dotsRibosomes, and the inner structure of mitochondria and chloroplasts

An electron microscope has much higher magnification and resolving power than a light microscope. This means it can be used to study cells in much finer detail, and it has let biologists see and understand many more sub-cellular structures.

How microscopy developed over time:

  • 1600s: early light microscopes. Robert Hooke named "cells" after seeing cork, and Antonie van Leeuwenhoek was the first to see bacteria.
  • 1800s: better light microscopes showed nuclei and, later, chromosomes.
  • 1930s onwards: the electron microscope was invented. By the 1950s it had revealed ribosomes and the folded membranes inside mitochondria, so scientists could link these structures to their functions.

The magnification equation

\[\text{magnification} = \dfrac{\text{size of image}}{\text{size of real object}}\]

Rearranged: size of image = magnification × size of real object, and size of real object = size of image ÷ magnification.

  • Both sizes must be in the same unit: \(1\text{ mm} = 1000\ \mu\text{m}\) and \(1\ \mu\text{m} = 1000\text{ nm}\).
  • Magnification has no unit; it is written with a times sign, such as × 400.
  • The total magnification of a light microscope is the eyepiece lens magnification multiplied by the objective lens magnification: a × 10 eyepiece with a × 4 objective gives × 40.

Finding the real size

In an electron micrograph at × 15 000, a mitochondrion is 30 mm long. Calculate its real length in μm.

\(\text{size of real object} = \dfrac{\text{size of image}}{\text{magnification}} = \dfrac{30}{15\,000} = 0.002\text{ mm}\)

Convert: \(0.002 \times 1000 = 2\ \mu\text{m}\)

Check: mitochondria are a few μm long, so the answer is sensible.

Magnification in standard form

A chloroplast 4 μm long is drawn 50 mm long. Calculate the magnification of the drawing. Give your answer in standard form.

Same units: \(50\text{ mm} = 50 \times 1000 = 50\,000\ \mu\text{m}\)

\(\text{magnification} = \dfrac{50\,000}{4} = 12\,500\)

In standard form the magnification is \(1.25 \times 10^{4}\).

Diagram of a light microscope, seen from the side. A light microscope seen from the side. An eyepiece lens sits on top of the body tube; below it a rotating disc carries three objective lenses of different lengths pointing down. A slide lies on the stage, held down by two clips, above a lamp on the base. A large coarse focusing knob and a smaller fine focusing knob are on the arm that joins the base to the tubes. The label "eyepiece lens" points to the eyepiece lens; the label "objective lens" points to an objective lens; the label "stage" points to the stage; the label "clip" points to the stage clips; the label "lamp" points to the lamp (light source); the label "coarse focusing knob" points to the coarse focusing knob; the label "fine focusing knob" points to the fine focusing knob.
The main parts of a light microscope.

Required practical: Looking at cells with a light microscope

  1. Put a thin layer of cells (such as onion epidermis) on a slide with a drop of stain (iodine solution for onion cells), and lower a coverslip at an angle to avoid air bubbles.
  2. Clip the slide onto the stage and select the lowest-power objective lens: it shows a larger area, so the cells are easier to find.
  3. Looking from the side, turn the coarse focusing knob to bring the stage close to the lens without touching it.
  4. Looking through the eyepiece, turn the coarse focusing knob to move the stage away until the cells are roughly in focus, then sharpen the image with the fine focusing knob.
  5. For more detail, change to a higher-power objective and refocus with the fine focusing knob only, so the lens does not hit the slide.
  6. Draw what you see with clear, unshaded pencil lines, label it with ruled lines, and include a magnification or scale bar.

To estimate a cell's size, divide the width of the field of view by the number of cells across it. Safety: iodine solution irritates the eyes, so wear eye protection.

Remember

  • magnification = size of image ÷ size of real object.
  • Resolution is the ability to distinguish between two points close together.
  • Electron microscopes have much higher magnification and resolution, revealing many more sub-cellular structures.
  • 1 mm = 1000 μm and 1 μm = 1000 nm.

Common mistakes

  • Adding the eyepiece and objective magnifications. Multiply them.
  • Describing resolution as "how clear" or "how big" the image is. It is the ability to distinguish two close points as separate.
  • Saying an electron microscope is better only because it magnifies more. Its much higher resolution is what reveals small structures.
  • Dividing a size in mm by a size in μm without converting one of them first.
  • Using the coarse focusing knob with the high-power lens, which can crash the lens into the slide.

Exam tip

In magnification calculations, write the equation, substitute, convert units and give the unit in your answer: working gains marks even if the final answer is wrong. Then check your answer is sensible: most animal and plant cells are 10-100 μm across.

Study Helper Hints first, answers after you try

Stuck on this one? Ask for a hint and I’ll point you in the right direction, without giving the answer away. Once you’ve checked your answer, I’ll show you how the marks are awarded.