Level:
Correct: 0
Incorrect: 0
Marks: 0/0
Exam Practice
Course:
Topics:
Avg
score:
–
Topics
done:
0/30

Mains electricity

Practise 14 exam-style questions on Mains electricity for AQA GCSE Combined Science (Physics Paper 1). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 14 questions
  • 1–6 marks each
  • Instant marking
  • No sign-up needed
14 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

1 mark

What is the potential difference between the live wire of the UK mains supply and earth?

Model answer

About 230 V.

Explanation

The earth is taken as 0 V. The live wire carries the alternating potential difference of the supply, so there is about 230 V between it and earth.

Mark scheme
  1. 1 mark

    about 230 V

    allow 230 V; allow 240 V

Question 2

2 marks

The on/off switch in a mains appliance is always connected in the live wire, not in the neutral wire.

Suggest why.

Model answer

With the switch in the live wire, opening the switch disconnects the appliance from the 230 V live supply. The parts inside the appliance are then at about 0 V, so there is much less danger of an electric shock if someone touches them.

Explanation

If the switch were in the neutral wire, the appliance would stop working when switched off, but its internal parts would still be connected to the live wire at 230 V, so it could still give a shock.

Mark scheme
  1. 1 mark

    when the switch is open, the appliance is disconnected from the live wire / from the 230 V supply

  2. 1 mark

    so the parts inside the appliance are not live / there is less danger of a shock if someone touches them

Question 3

3 marks

A three-core mains cable contains a live wire, a neutral wire and an earth wire.

Describe the job of each wire.

Model answer

The live wire carries the alternating potential difference from the supply. The neutral wire completes the circuit so that the current can return. The earth wire is a safety wire that stops the appliance becoming live if there is a fault.

Explanation

In normal use the current flows in through the live wire and out through the neutral wire. The earth wire normally carries no current; it is there only for safety.

Mark scheme
  1. 1 mark

    live: carries the alternating potential difference from the supply

    allow it is at about 230 V

  2. 1 mark

    neutral: completes the circuit

    allow the current returns to the supply through it

  3. 1 mark

    earth: a safety wire that stops the appliance becoming live

    allow it only carries a current if there is a fault

Question 4

3 marks

A metal-cased electric fire is working normally. It is connected to the mains with a three-core cable.

Which wires in the cable carry a current? Explain your answer.

Model answer

Only the live wire and the neutral wire carry a current. The live wire carries the alternating potential difference from the supply, and the current flows through the heater and back through the neutral wire, which completes the circuit. The earth wire carries no current because it only carries a current if there is a fault.

Explanation

In normal use the earth wire is not part of the working circuit. It is connected to the metal case purely for safety, ready to carry a current if a fault makes the case live.

Mark scheme
  1. 1 mark

    the live wire and the neutral wire

    do not accept if the earth wire is included

  2. 1 mark

    the current flows through the appliance between the live wire and the neutral wire, which completes the circuit

    allow the live carries the potential difference from the supply and the neutral completes the circuit

  3. 1 mark

    the earth wire carries no current because it only carries a current if there is a fault

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Revision notes

Mains electricity

The big idea

Most appliances are connected to the mains with a three-core cable: live, neutral and earth. Each wire has a job, a colour and a potential. The danger always comes from the live wire, which is at about 230 V compared with the ground, so you need to explain when and why it can give a shock.

The three wires

Each wire is copper, a good conductor, covered in plastic insulation that is colour coded so the wires are easy to identify and connect correctly.

WireColourPotentialJob
LiveBrownAbout 230 V relative to earthCarries the alternating potential difference from the supply
NeutralBlueAt, or close to, earth potential (0 V)Completes the circuit
EarthGreen and yellow stripes0 VA safety wire that stops the appliance becoming live; it only carries a current if there is a fault

In normal use the current flows in through the live wire, through the appliance and out through the neutral wire. The earth wire carries no current at all.

Why the live wire is dangerous

A person standing on the ground is at earth potential, 0 V. If they touch the live wire, there is a potential difference of about 230 V across their body, so a current flows through them to earth. This electric shock can be fatal. They do not need to touch the neutral wire: the ground completes the circuit.

A live wire may be dangerous even when a switch is open. A switch only breaks the circuit at one point, so everything between the live supply and the switch is still at 230 V. If a switch has been wrongly fitted in the neutral wire, the appliance itself stays connected to the live wire and is still at 230 V when it is switched off. That is why switches and fuses go in the live wire, and why the supply must be switched off at the mains (the consumer unit) before anyone works on wiring.

Circuit diagram. All the components are connected in series in a single loop. Going round the loop from the a.c. power supply (labelled 230 V): point L; then an open switch (because it is open, no current flows anywhere in the circuit); then a lamp; then point N; and back to the supply.
L is joined to the live wire and N to the neutral wire. The switch is on the live side, so opening it cuts the lamp off from the live wire.

Any connection between live and earth is dangerous

  • Through a person: a current flows through the body to earth. Wet skin has a much lower resistance, so the current is larger, which is why bathroom lights use a pull cord.
  • Through a low-resistance path: the current is very large, which heats the wires strongly and could start a fire.

The earth wire uses this second idea safely. It is connected to the metal case of an appliance. If a fault makes the live wire touch the case, a large current flows through the low-resistance earth wire to earth, so the case stays at about 0 V instead of becoming live. The large current also melts the fuse (or trips the circuit breaker), which disconnects the live supply. Appliances with a plastic case cannot become live, so they use two-core cable with no earth wire.

A bird on a live cable

A bird can perch on a bare live cable without harm, but a person standing on the ground who touches the same cable could be killed. Explain why.

  • The live cable is at a high potential compared with earth (0 V).
  • Both of the bird's feet are on the same cable, at the same potential, and it touches nothing connected to earth. So there is almost no potential difference across its body, and no current flows through it.
  • The person on the ground is at earth potential, 0 V, so touching the cable puts a large potential difference across their body.
  • This connects the live wire to earth through the person, so a current flows through them to earth: an electric shock that could kill.

Common mistakes

  • Saying the earth wire carries a current in normal use or "completes the circuit". It only carries a current if there is a fault; the neutral wire completes the circuit.
  • Saying the neutral wire is always safe to touch. It is only close to 0 V, and if the wiring is wrong it could be at 230 V.
  • Thinking a light is safe to work on once it is switched off at the wall switch. Switch off at the mains.
  • Giving the earth colour as "green" or "yellow". Both are needed: green and yellow stripes.
  • Saying a shock happens because "electricity flows into you". Explain it with the potential difference between the live wire (230 V) and the person (0 V).

Exam tip

For shock questions, write the chain: live wire at 230 V, person at 0 V, so a large potential difference across the body, so a current flows through the person to earth. For the earth wire, add: low-resistance path, case stays at 0 V, large current melts the fuse.

Study Helper Hints first, answers after you try

Stuck on this one? Ask for a hint and I’ll point you in the right direction, without giving the answer away. Once you’ve checked your answer, I’ll show you how the marks are awarded.