Level:
Correct: 0
Incorrect: 0
Marks: 0/0
Exam Practice
Course:
Topics:
Edexcel GCSE Physics (Paper 2) Smart practice A mixed round aimed at your weak spots
Unit 1
Key concepts of physics
Unit 8
Energy - forces doing work
Unit 9
Forces and their effects
Unit 10
Electricity and circuits
Unit 11
Static electricity
Unit 12
Magnetism and the motor effect
Unit 13
Electromagnetic induction
Unit 14
Particle model
Unit 15
Forces and matter
Avg
score:
–
Topics
done:
0/34

The turns ratio and high-voltage transmission

Practise 13 exam-style questions on The turns ratio and high-voltage transmission for Edexcel GCSE Physics (Paper 2). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 13 questions
  • 1–6 marks each
  • Instant marking
  • No sign-up needed
13 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

1 mark

A student's laboratory transformer has 240 turns on its primary coil and 60 turns on its secondary coil. A voltmeter connected across the secondary coil reads 3.0 V.

Use the equation
Vp ÷ Vs = Np ÷ Ns

What is the p.d. across the primary coil?

Choose your answer.

  • A 0.75 V
  • B 12 V
  • C 4.0 V
  • D 720 V

Model answer

B - 12 V.

Explanation

Rearrange the equation to make Vp the subject: Vp = Vs × Np ÷ Ns = 3.0 × 240 ÷ 60 = 12 V. The primary coil has four times as many turns as the secondary coil, so the p.d. across it is four times as large. Checking which coil has more turns is a quick way to spot an upside-down ratio such as 0.75 V.

Mark scheme
  1. 1 mark

    B / 12 V (1)

    The only correct answer is B: Vp = Vs × Np ÷ Ns = 3.0 × 240 ÷ 60 = 12 V. A is not correct because it is 3.0 × 60 ÷ 240, which uses the turns ratio upside down (it would make this step-down transformer a step-up one). C is not correct because it is 240 ÷ 60, the turns ratio alone, not multiplied by the secondary p.d. D is not correct because it is 3.0 × 240, which ignores the number of turns on the secondary coil. Accept the letter or the option. If more than one option is given, do not award the mark.

Question 2

2 marks

The national grid in Great Britain transmits electricity at up to 400 kV. Transmitting at an even higher p.d. would reduce the power wasted in the cables still further.

Suggest two reasons why the p.d. is not made much higher.

Model answer

A much higher p.d. would need much larger insulators and bigger gaps between the cables and the pylons or the ground to stop sparks jumping across, so the pylons would have to be taller and more expensive. The transformers would also be bigger and more expensive, and the power wasted at 400 kV is already a small fraction, so the extra saving would not be worth the cost.

Explanation

Choosing a transmission p.d. is a balance: a higher p.d. means a smaller current and less heating of the cables, but it needs more insulation, larger clearances and more expensive transformers, and it is more dangerous. Because the power wasted depends on 1 ÷ V², each further increase saves less. Answers must give reasons against a higher p.d., not repeat its advantages.

Mark scheme
  1. 1 mark

    a higher p.d. needs more / larger insulators and larger gaps (taller pylons) to stop sparks / arcing from the cables to the pylons or the ground (1)

    Any two from the four points; max 2. Accept 'the insulation would have to be much thicker'.

  2. 1 mark

    transformers (and other equipment) for a higher p.d. are larger / more expensive (1)

    Accept 'the cost of the extra equipment would be more than the value of the energy saved'.

  3. 1 mark

    a higher p.d. is more dangerous (people must be kept further away from the lines) (1)

    Accept 'a greater risk of fatal electric shock to workers'. 'It is dangerous' on its own needs the idea of more danger at the higher p.d.

  4. 1 mark

    the power wasted in the cables is already a small fraction, so the extra saving would be small (1)

    Accept 'raising the p.d. further gives diminishing savings'. Do not accept 'the power wasted would increase' or 'the cables would get hotter'.

Question 3

4 marks

On building sites, power tools are usually supplied at 110 V from a site transformer, not at 230 V from the mains. The transformer's secondary coil is earthed at its centre point, so the p.d. between either end of the secondary coil and earth is half of the p.d. across the whole secondary coil.
(Source: Health and Safety Executive)

A site transformer has 920 turns on its primary coil and 440 turns on its secondary coil. Its primary coil is supplied from the 230 V mains.

Show that the p.d. between either end of the secondary coil and earth is 55 V, and explain why this makes the tools safer to use.

Use the equation
Vp ÷ Vs = Np ÷ Ns

Model answer

Vp ÷ Vs = Np ÷ Ns
Vs = Vp × Ns ÷ Np = 230 × 440 ÷ 920 = 110 V
The secondary coil is earthed at its centre, so the p.d. between either end and earth is 110 ÷ 2 = 55 V.

If a worker touches a live wire, for example where a cable has been damaged, while in contact with earth, the p.d. across their body is at most 55 V instead of 230 V. The current through their body is therefore much smaller, so the electric shock is much less dangerous.

Explanation

The turns ratio gives the p.d. across the whole secondary coil, 110 V; earthing its centre means each end is only 55 V from earth, because each half has 220 turns. In a 'show that' question every step must be written down, and the final value should be stated. The safety benefit is that a smaller p.d. drives a smaller current through a person's body, which is why the Health and Safety Executive recommends this system for site tools.

Mark scheme
  1. 1 mark

    substitution and rearrangement: Vs = 230 × 440 ÷ 920 (1)

    A correct answer with no working scores 0 for the first three marking points; the working must be seen. Accept 230 ÷ Vs = 920 ÷ 440.

  2. 1 mark

    evaluation: Vs = 110 (V) (1)

    Accept 110.0 V.

  3. 1 mark

    110 ÷ 2 = 55 (V) / 230 × 220 ÷ 920 = 55 (V) (1)

    Accept 'half the secondary coil (220 turns) gives 55 V'. The step from the whole secondary to half of it must be seen; 55 V written without it does not score.

  4. 1 mark

    a person touching a live part / a damaged cable (while in contact with earth) has a smaller p.d. across them, so a smaller current passes through them and the electric shock is less dangerous / less likely to kill (1)

    The smaller p.d. must be linked to a smaller current or a less severe shock. Do not accept 'less electricity' or 'it is safer because it is a lower voltage' on its own. Ignore references to fuses.

Question 4

5 marks

A solar farm produces 6.6 MW. A step-up transformer at the solar farm increases the p.d. from 11 kV before the electricity is sent along a cable to the grid. The cable has a total resistance of 1.65 Ω. The primary coil of the transformer has 500 turns.

The engineers want no more than 1.0% of the 6.6 MW to be wasted heating the cable.

Calculate the smallest number of turns the secondary coil can have. Assume that the transformer is 100% efficient.

Use the equation
Vp ÷ Vs = Np ÷ Ns

Model answer

Largest power wasted = 1.0% of 6 600 000 W = 66 000 W
P = I² × R, so I² = 66 000 ÷ 1.65 = 40 000 and I = 200 A (the largest current allowed)
P = I × V, so V = 6 600 000 ÷ 200 = 33 000 V (the smallest p.d. allowed)
Vp ÷ Vs = Np ÷ Ns: 11 000 ÷ 33 000 = 500 ÷ Ns
Ns = 500 × 33 000 ÷ 11 000 = 1500 turns

Explanation

Work backwards from the limit: the largest power wasted gives the largest current the cable can carry (from P = I² × R), and that current gives the smallest p.d. needed to transmit 6.6 MW (from P = I × V). The turns ratio then gives the number of secondary turns; any more turns than 1500 would give a higher p.d. and waste even less. Forgetting to take the square root of I² is the most common error.

Mark scheme
  1. 1 mark

    largest power wasted = 1.0% of 6.6 MW = 66 000 (W) (1)

    An answer of 1500 (turns) with no working scores 5 marks. Accept 'at least 1500'. Allow ecf at each step from the student's earlier values, except as noted below. Using the 66 000 W of marking point 1 as the secondary p.d. (giving 3000 turns) is a wrong method: it scores marking points 1 and 4 only.

  2. 1 mark

    (I² = 66 000 ÷ 1.65, so) largest current I = 200 (A) (1)

    Not taking the square root (I = 40 000 A) is a wrong method: it scores 0 for this mark and for marking points 3 and 5, but marking point 4 may still be awarded for a correct substitution of the student's p.d. into the turns ratio equation.

  3. 1 mark

    smallest p.d. V = P ÷ I = 6 600 000 ÷ 200 = 33 000 (V) (1)

    Accept 33 kV. The power in the cable is 6.6 MW because the transformer is 100% efficient.

  4. 1 mark

    substitution: 11 000 ÷ 33 000 = 500 ÷ Ns (1)

    Allow the p.d.s both in kV (11 ÷ 33 = 500 ÷ Ns). Allow ecf from the student's value of V.

  5. 1 mark

    evaluation: Ns = 1500 (1)

    An answer with a power of ten error (e.g. 150 or 15 000), from a correct method, scores 4 marks.

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Study Helper Hints first, answers after you try

Stuck on this one? Ask for a hint and I’ll point you in the right direction, without giving the answer away. Once you’ve checked your answer, I’ll show you how the marks are awarded.