Mains electricity and electrical safety

Practise 18 exam-style questions on Mains electricity and electrical safety for Edexcel GCSE Physics (Paper 2). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 18 questions
  • 1–6 marks each
  • Instant marking
  • No sign-up needed
18 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

1 mark

In the plug of an electrical appliance, the fuse is connected in the live wire.

Why is the fuse connected in the live wire and not in the neutral wire?

Choose your answer.

  • A only the live wire has a current
  • B the neutral wire is at about 230 V
  • C the fuse melts faster in the live wire
  • D it cuts the device off from 230 V

Model answer

D - when the fuse melts, it cuts the device off from the 230 V live wire.

Explanation

A fuse in the neutral wire would still stop the current when it melted, but the appliance would remain connected to the live wire at 230 V, so touching a faulty part could still give a shock. With the fuse in the live wire, a melted fuse isolates the appliance from the high p.d. The current is the same in the live and neutral wires.

Mark scheme
  1. 1 mark

    D / it cuts the device off from 230 V (1)

    The only correct answer is D: when a fuse in the live wire melts, the appliance is disconnected from the live wire, which is at about 230 V, so no part of the appliance is left at a high p.d. A is not correct because the live and neutral wires are in series with the appliance, so the current in them is the same. B is not correct because the neutral wire is at about 0 V; it is the live wire that is at about 230 V. C is not correct because the current is the same in both wires, so a fuse would melt at the same current in either; the reason is what happens after it melts. Accept the letter or the option. If more than one option is given, do not award the mark.

Question 2

2 marks

The wires in a UK domestic mains circuit are the live wire, the neutral wire and the earth wire.

State the potential difference between:
- the live wire and the earth wire
- the neutral wire and the earth wire.

Model answer

Between the live wire and the earth wire: about 230 V.
Between the neutral wire and the earth wire: about 0 V.

Explanation

The live wire is at about 230 V compared with earth, while the neutral wire is at or very close to earth potential, so there is about 0 V between neutral and earth. This is why touching the live wire is dangerous even if you do not touch the neutral wire.

Mark scheme
  1. 1 mark

    (live and earth:) (about) 230 V (1)

    Accept values from 216 V to 253 V (the legal limits of the UK supply). Ignore 'alternating'. Do not accept 50 V or 230 Hz.

  2. 1 mark

    (neutral and earth:) (about) 0 V (1)

    Accept 'zero', 'none' or 'very small / close to 0 V'. The two answers must be matched to the correct pairs of wires.

Question 3

3 marks

A steam iron has a power of 1.2 kW. It is connected to the 230 V mains supply.

The plug of the steam iron needs a fuse. Fuses are available with ratings of 3 A, 5 A and 13 A. A fuse melts if the current in it becomes greater than its rating.

Determine which fuse is the most suitable for the steam iron. Give a reason for your choice.

Model answer

P = I × V, so I = P ÷ V = 1200 ÷ 230 = 5.2 A
The 13 A fuse is the most suitable. The normal current of 5.2 A is greater than 5 A, so a 3 A or a 5 A fuse would melt as soon as the iron was switched on. The 13 A fuse is the smallest rating above the normal current, so it will not melt in normal use but will melt if a fault makes the current much larger than normal.

Explanation

First find the normal current with I = P ÷ V (5.2 A), then choose the smallest fuse rating above it. The fuse must not melt in normal use, so the 5 A fuse is not suitable even though 5.2 A is only a little more than 5 A; the 13 A fuse is needed (UK guidance also gives 13 A fuses to appliances above about 700 W). Rounding the current down to 5 A, or forgetting to convert 1.2 kW to 1200 W, are the common errors.

Mark scheme
  1. 1 mark

    substitution and rearrangement: (I =) 1200 ÷ 230 (1)

    A correct current with no working scores this mark and the next.

  2. 1 mark

    evaluation: 5.2 (A) (1)

    Allow values that round to 5.2 (A), e.g. 5.22. An answer of 5.2 to any other power of ten scores 1 of the two calculation marks (power of ten error). If the only error is 1.2 kW not converted to W (1.2 ÷ 230 = 0.0052 A), only this mark is lost: the answer scores the substitution mark and the fuse mark as ecf (with a reason).

  3. 1 mark

    13 A, because the current (5.2 A) is greater than 5 A, so a 3 A or 5 A fuse would melt in normal use / 13 A is the smallest rating above the normal current (1)

    The choice and a reason are both needed for this mark. Allow ecf: the smallest rating above the student's calculated current, with a reason. Do not accept 5 A (the normal current of 5.2 A is greater than 5 A, so the fuse would melt as soon as the iron was used; rounding 5.2 A down to 5 A does not justify it). A choice with no calculated current scores 0 for this mark. This follows Pearson's model (sample assessment materials, Paper 6 Q6(a)(i), where the rating of a fuse is the current above which it melts): the most suitable fuse has the smallest rating above the normal current. UK fire and rescue service guidance (13 A fuses for appliances of about 700 W to 3000 W) gives the same choice.

Question 4

4 marks

UK law says that the mains supply to a home should have a potential difference of 230 V, but it is allowed to be up to 10% higher or 6% lower than this.
(Source: Electricity Safety, Quality and Continuity Regulations 2002)

An electric heater has a power of 2.3 kW when the p.d. across it is 230 V.

Calculate the power of the heater when the p.d. across it is the highest value allowed.

Assume that the resistance of the heater does not change.

Model answer

Highest p.d. = 230 × 1.10 = 253 V
At 230 V: I = P ÷ V = 2300 ÷ 230 = 10 A, so R = V ÷ I = 230 ÷ 10 = 23 Ω
At 253 V: I = V ÷ R = 253 ÷ 23 = 11 A
P = I × V = 11 × 253 = 2783 W (about 2.8 kW)

Explanation

With a constant resistance, a higher p.d. drives a larger current, so both the current and the p.d. increase by 10% and the power increases by about 21%: from 2300 W to 2783 W. Find the resistance first (23 Ω), then the new current (11 A) and the new power. Multiplying the power by 1.10 only is a common error, because it ignores the increase in current.

Mark scheme
  1. 1 mark

    highest p.d. = 230 × 1.10 = 253 (V) (1)

    An answer of 2783 (W) with no working scores 4 marks. Accept 1.10 used as the factor by which the p.d. increases (e.g. in 1.10² = 1.21) for this mark.

  2. 1 mark

    (I = 2300 ÷ 230 = 10 A, so) resistance = 230 ÷ 10 = 23 (Ω) (1)

    Accept R = 230² ÷ 2300 = 23 Ω. Alternative method: power is proportional to p.d.² when the resistance is constant, so the power is multiplied by 1.10² (= 1.21); this scores this mark and the next.

  3. 1 mark

    new current = 253 ÷ 23 = 11 (A) (1)

    Allow ecf from an incorrect p.d. or resistance. Alternative method: 2300 × 1.21 seen.

  4. 1 mark

    (P = 11 × 253 =) 2783 (W) (1)

    Accept values that round to 2800 W, e.g. 2780 W or 2.8 kW. Allow ecf from earlier steps. 2530 W (2300 × 1.10 or 10 × 253, assuming the current stays the same) is a wrong method: it scores the first mark only, and only if 253 V is seen. If the only error is 2.3 kW not converted to W (e.g. R = 23 000 Ω, I = 0.011 A, P = 2.78 W), only one mark is lost: the answer scores 3 marks. A final answer of 2.78 kW (or 2.8 kW) is correct and scores 4 marks.

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Study Helper Hints first, answers after you try

Stuck on this one? Ask for a hint and I’ll point you in the right direction, without giving the answer away. Once you’ve checked your answer, I’ll show you how the marks are awarded.