Level:
Correct: 0
Incorrect: 0
Marks: 0/0
Exam Practice
Course:
Topics:
Edexcel GCSE Biology (Paper 2) Smart practice A mixed round aimed at your weak spots
Unit 1
Key concepts in biology
Unit 6
Plant structures and their functions
Unit 7
Animal coordination, control and homeostasis
Unit 8
Exchange and transport in animals
Unit 9
Ecosystems and material cycles
Avg
score:
–
Topics
done:
0/38

Microscopes, size and scale

Practise 12 exam-style questions on Microscopes, size and scale for Edexcel GCSE Biology (Paper 2). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 12 questions
  • 1–6 marks each
  • Instant marking
  • No sign-up needed
12 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

1 mark

A transmission electron microscope can show much finer detail than a light microscope.

Which of these is the reason why an electron microscope has a much higher resolution than a light microscope?

Choose your answer.

  • A its lenses are made of better glass
  • B its specimens are always alive
  • C electrons have a shorter wavelength
  • D its image is made much larger

Model answer

C electrons have a shorter wavelength

Explanation

Resolution depends on the wavelength used: the shorter the wavelength, the closer together two points can be and still be seen as separate. Choosing D confuses resolution with magnification - making an image bigger does not reveal more detail.

Mark scheme
  1. 1 mark

    C / electrons have a shorter wavelength (1)

    The only correct answer is C: the resolution of a microscope is limited by the wavelength of the radiation it uses, and a beam of electrons has a much shorter wavelength than light, so much smaller details can be seen as separate. A is not correct because an electron microscope focuses the electron beam with magnets (electromagnetic lenses), not glass lenses; B is not correct because specimens for an electron microscope must be dead, as they are placed in a vacuum; D is not correct because a larger image does not show more detail unless the resolution is also higher. Accept the letter or the option. If more than one option is given, do not award the mark.

Question 2

2 marks

A textbook states that the total surface area of the alveoli in the lungs of an adult is about 70 m².

Give this area in mm².

Give your answer in standard form.

Model answer

1 m = 1000 mm, so 1 m² = 1000 × 1000 = 10⁶ mm²
70 m² = 70 × 10⁶ mm² = 7 × 10⁷ mm²

Explanation

When converting an area, the length conversion factor must be squared: 1 m = 10³ mm, so 1 m² = (10³)² = 10⁶ mm². Multiplying by 1000 only, which gives 7 × 10⁴ mm², is the most common error, and 70 × 10⁶ is not in standard form because 70 is not between 1 and 10.

Mark scheme
  1. 1 mark

    1 m² = 1000 × 1000 = 1 000 000 / 10⁶ mm² / 70 × 10⁶ (1)

    An answer of 7 × 10⁷ (mm²) with no working scores 2 marks. accept 70 000 000 for this mark.

  2. 1 mark

    7 × 10⁷ (mm²) (1)

    accept 7.0 × 10⁷. The answer must be in standard form for this mark: 70 000 000 scores 1 mark. 7 × 10⁴ (the conversion factor not squared) scores 0.

Question 3

3 marks

A light microscope uses visible light with a wavelength of about 550 nm. A transmission electron microscope uses a beam of electrons with a wavelength of about 2.5 pm. The shorter the wavelength, the smaller the details that a microscope can resolve.

Calculate how many times shorter the wavelength of the electrons is than the wavelength of the light.

Give your answer in standard form.

Model answer

550 nm = 550 × 1000 = 550 000 pm
550 000 ÷ 2.5 = 220 000
The wavelength of the electrons is 2.2 × 10⁵ times shorter.

Explanation

Both wavelengths must be in the same unit before dividing: 1 nm = 1000 pm, or convert both into metres (nano = 10⁻⁹, pico = 10⁻¹²). The electron wavelength is over 200 000 times shorter, which is why an electron microscope can resolve details such as membranes and ribosomes that a light microscope never can.

Mark scheme
  1. 1 mark

    both wavelengths in the same unit, e.g. 550 nm = 550 000 pm / 550 nm = 5.5 × 10⁻⁷ m and 2.5 pm = 2.5 × 10⁻¹² m / 2.5 pm = 0.0025 nm (1)

    An answer of 2.2 × 10⁵ with no working scores 3 marks.

  2. 1 mark

    550 000 ÷ 2.5 = 220 000 / 5.5 × 10⁻⁷ ÷ 2.5 × 10⁻¹² (1)

    accept 550 ÷ 0.0025 = 220 000; ecf from an incorrect conversion for this mark only if the division is the right way round.

  3. 1 mark

    2.2 × 10⁵ (1)

    the answer must be in standard form for this mark: 220 000 scores 2 marks. accept 2.20 × 10⁵. award 2 marks for 2.2 × 10ⁿ with any other power of ten (an incorrect unit conversion), e.g. 2.2 × 10² or 2.2 × 10⁸. An inverted ratio (4.5 × 10⁻⁶) scores marking point 1 only.

Question 4

4 marks

A student wanted to estimate the number of stomata on the lower surface of a leaf. She looked at a thin peel of the lower epidermis with a light microscope and counted the stomata in five different fields of view. The area of each field of view was 0.16 mm².

The table shows her counts.

The area of the lower surface of the leaf was 45 cm².

Estimate the number of stomata on the lower surface of the leaf.

Give your answer in standard form to 2 significant figures.

Table with columns "Field of view", "1", "2", "3", "4", "5". Field of view: Number of stomata; 1: 28; 2: 33; 3: 30; 4: 35; 5: 29.

Model answer

Mean number of stomata per field of view = (28 + 33 + 30 + 35 + 29) ÷ 5 = 155 ÷ 5 = 31
Number per mm² = 31 ÷ 0.16 = 193.75
Area of leaf = 45 cm² = 45 × 100 = 4500 mm²
Number of stomata = 193.75 × 4500 = 871 875
= 8.7 × 10⁵ (2 significant figures)

Explanation

Counting every stoma on a leaf would take far too long, so the student counts a sample of fields of view, finds the mean and scales up. Area conversions use the square of the length conversion: 1 cm = 10 mm, so 1 cm² = 100 mm², and using 10 instead of 100 is the commonest error.

Mark scheme
  1. 1 mark

    (mean =) (28 + 33 + 30 + 35 + 29) ÷ 5 = 31 (1)

    An answer of 8.7 × 10⁵ (stomata) with no working scores 4 marks.

  2. 1 mark

    (31 ÷ 0.16 =) 193.75 (stomata per mm²) (1)

    accept 194 / 190. Alternative method: number of fields of view in the leaf = 4500 ÷ 0.16 = 28 125 for this mark. ecf from an incorrect mean.

  3. 1 mark

    (45 cm² =) 4500 (mm²) (1)

    accept the leaf area converted correctly in any working, e.g. 193.75 per mm² = 19 375 per cm².

  4. 1 mark

    8.7 × 10⁵ (stomata) (1)

    the answer must be in standard form and to 2 significant figures for this mark: 871 875, 870 000 or 8.72 × 10⁵ score 3 marks. ecf from an incorrect mean or density, if the method is correct. 8.7 × 10⁴ or 8.7 × 10⁶ (an incorrect area conversion, e.g. 45 cm² taken as 450 mm²) score marking points 1 and 2 only. 2.2 × 10⁴ (multiplying the mean by 0.16 instead of dividing) scores marking points 1 and 3 only if the conversion is seen.

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Study Helper Hints first, answers after you try

Stuck on this one? Ask for a hint and I’ll point you in the right direction, without giving the answer away. Once you’ve checked your answer, I’ll show you how the marks are awarded.