Level:
Correct: 0
Incorrect: 0
Marks: 0/0
Exam Practice
Course:
Topics:
OCR GCSE Physics (Paper 3) Smart practice A mixed round aimed at your weak spots
Unit 1
Matter
Unit 2
Forces
Unit 3
Electricity
Unit 4
Magnetism and magnetic fields
Unit 9
Practical skills
Avg
score:
–
Topics
done:
0/36

Transformers

Practise 14 exam-style questions on Transformers for OCR GCSE Physics (Paper 3). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 14 questions
  • 1–6 marks each
  • Instant marking
  • No sign-up needed
14 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

1 mark

A transformer for a set of garden lights changes the 230 V mains supply to 12 V. Its secondary coil has 60 turns.

Use the equation: potential difference across primary coil ÷ potential difference across secondary coil = number of turns in primary coil ÷ number of turns in secondary coil

How many turns are on the primary coil?

Choose your answer.

  • A 3
  • B 46
  • C 1150
  • D 13 800

Model answer

C: 230 ÷ 12 = Np ÷ 60, so Np = 230 × 60 ÷ 12 = 1150 turns.

Explanation

Substitute the three known values into the equation and rearrange: Np = Vp × Ns ÷ Vs. A quick check is that the transformer steps the p.d. down by a factor of 230 ÷ 12 = 19.2, so the primary coil must have 19.2 times as many turns as the secondary coil. Turning the ratio upside down gives a primary coil with fewer turns than the secondary coil, which would step the p.d. up.

Mark scheme
  1. 1 mark

    C / 1150

    The only correct answer is C: 230 ÷ 12 = number of turns in primary coil ÷ 60, so the number of turns in the primary coil = 230 × 60 ÷ 12 = 1150. A is not correct because 3 comes from 60 × 12 ÷ 230 = 3.1, with the ratio upside down: a step-down transformer must have more turns on its primary coil than on its secondary coil; B is not correct because 46 comes from 230 × 12 ÷ 60, a wrong rearrangement of the equation; D is not correct because 13 800 is 230 × 60, which leaves out the division by 12. ALLOW the letter or the option. If more than one option is given, do not award the mark.

Question 2

2 marks

A hair dryer from the UK is designed to work on a 230 V supply. The manufacturer's instructions say that the potential difference across it must be between 220 V and 240 V. In the USA, the mains supply is 120 V.

A traveller buys a step-up transformer to use the hair dryer in the USA. Its primary coil has 500 turns and is connected to the 120 V supply. Its secondary coil has 1050 turns and is connected to the hair dryer.

Use the equation: potential difference across primary coil ÷ potential difference across secondary coil = number of turns in primary coil ÷ number of turns in secondary coil

Use a calculation to decide whether the hair dryer can be used safely with this transformer.

Model answer

120 ÷ Vs = 500 ÷ 1050
Vs = 120 × 1050 ÷ 500 = 252 V
252 V is more than 240 V, so the p.d. across the hair dryer would be too high: it cannot be used safely with this transformer.

Explanation

Find the secondary p.d. from the turns ratio, then compare it with the range in the instructions. The secondary coil has 2.1 times as many turns as the primary coil, so the p.d. is stepped up 2.1 times, to 252 V; a secondary coil of about 960 turns would give about 230 V. Putting the ratio upside down gives 57 V, which should be rejected because a step-up transformer must increase the p.d.

Mark scheme
  1. 1 mark

    120 ÷ p.d. across secondary coil = 500 ÷ 1050, so p.d. across secondary coil = 120 × 1050 ÷ 500 = 252 (V); or a correct final answer of 252 V with no working

    An answer of 252 V with no working scores marking point 1; marking point 2 needs the decision. ALLOW any correct rearrangement, for example 120 × 2.1. An answer of 57 V (from 120 × 500 ÷ 1050, the ratio upside down) scores 0 for this mark: a step-up transformer must give a larger p.d. than its supply.

  2. 1 mark

    (no:) 252 V is more than 240 V / is outside the range in the instructions, so the hair dryer cannot be used safely with this transformer

    The decision must agree with the calculated p.d.: ALLOW ECF from a wrong p.d. shown in the working (for example 57 V is below 220 V, so the hair dryer would not work properly). A decision with no calculated p.d. scores 0. IGNORE references to current or power.

Question 3

3 marks

A student makes a transformer to light a 2.5 V lamp from a 12 V a.c. supply. The primary coil has 480 turns.

She winds the secondary coil from a reel of insulated wire. Each turn of the secondary coil uses 0.13 m of wire.

Use the equation: potential difference across primary coil ÷ potential difference across secondary coil = number of turns in primary coil ÷ number of turns in secondary coil

Calculate the length of wire needed for the secondary coil.

Model answer

12 ÷ 2.5 = 480 ÷ Ns
Ns = 480 × 2.5 ÷ 12 = 100 turns
Length of wire = 100 × 0.13 = 13 m

Explanation

First use the turns-ratio equation to find the number of turns: the p.d. is stepped down by a factor of 12 ÷ 2.5 = 4.8, so the secondary coil needs 480 ÷ 4.8 = 100 turns. Then multiply the number of turns by the length of wire in each turn. A common error is to turn the ratio upside down, which gives 2304 turns and about 300 m of wire, the number for a step-up transformer.

Mark scheme
  1. 1 mark

    12 ÷ 2.5 = 480 ÷ number of turns in secondary coil / number of turns in secondary coil = 480 × 2.5 ÷ 12; or a correct final answer of 13 m with no working

    An answer of 13 m with no working scores 3 marks. ALLOW any correct rearrangement. ALLOW 1 mark for 300 m or 299.52 m (from 2304 turns, the ratio upside down, × 0.13).

  2. 1 mark

    (number of turns in secondary coil =) 100; or a correct final answer of 13 m with no working

    ALLOW 100 turns seen in the working.

  3. 1 mark

    (length of wire = 100 × 0.13 =) 13 (m)

    ALLOW ECF from a wrong number of turns shown in the working, for example 2304 × 0.13 = 300 m scores this mark only. ALLOW 1300 cm. IGNORE units unless a wrong unit is given with a value that does not match it.

Question 4

4 marks

A student connects two transformers, X and Y, one after the other. The secondary coil of X is connected to the primary coil of Y.

• Transformer X: 1200 turns on the primary coil and 300 turns on the secondary coil
• Transformer Y: 150 turns on the primary coil and 900 turns on the secondary coil

The primary coil of X is connected to a 20 V a.c. supply.

Use the equation: potential difference across primary coil ÷ potential difference across secondary coil = number of turns in primary coil ÷ number of turns in secondary coil

Calculate the p.d. across the secondary coil of Y.

Then give the ratio of the number of turns on the primary coil to the number of turns on the secondary coil for a single transformer that would have the same overall effect as X and Y together.

Model answer

Transformer X: 20 ÷ Vs = 1200 ÷ 300, so Vs = 20 × 300 ÷ 1200 = 5.0 V
This 5.0 V is the p.d. across the primary coil of Y.
Transformer Y: 5.0 ÷ Vs = 150 ÷ 900, so Vs = 5.0 × 900 ÷ 150 = 30 V
Overall the p.d. goes from 20 V to 30 V, so a single transformer would need a turns ratio (primary : secondary) of 20 : 30 = 2 : 3.

Explanation

Treat the transformers one at a time: the output of X becomes the input of Y. X steps the p.d. down by a factor of 4 and Y steps it up by a factor of 6, so overall it is stepped up by 6 ÷ 4 = 1.5 times. The single transformer therefore needs 1.5 times as many turns on its secondary coil as on its primary coil. Turning one of the ratios upside down is the most common error.

Mark scheme
  1. 1 mark

    p.d. across secondary coil of X (= p.d. across primary coil of Y) = 20 × 300 ÷ 1200 = 5.0 (V); or a correct final answer of 30 V with no working

    An answer of 30 V with no working scores marking points 1, 2 and 3. ALLOW the overall method: 20 × (300 ÷ 1200) × (900 ÷ 150) = 20 × 1.5 = 30 V scores marking points 1, 2 and 3. ALLOW 2 marks for 480 V (ratio of X upside down, giving 80 V, then 80 × 900 ÷ 150). An answer of 0.83 V (ratio of Y upside down) scores marking point 1 only.

  2. 1 mark

    p.d. across secondary coil of Y = 5.0 × 900 ÷ 150; or a correct final answer of 30 V with no working

    ALLOW ECF from a wrong p.d. for X shown in the working.

  3. 1 mark

    30 (V)

    ALLOW ECF from marking point 2.

  4. 1 mark

    the ratio of primary turns to secondary turns is two to three / the secondary coil has one and a half times as many turns as the primary coil (a step-up transformer)

    ALLOW 2 : 3, 2/3, 0.67, 1 : 1.5, or any pair of numbers in this ratio, for example 200 : 300. ALLOW ECF from the p.d. found for Y: 20 : that p.d. DO NOT ALLOW 3 : 2 unless it is clearly stated as secondary : primary. IGNORE a correct ratio given for X or Y alone.

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Study Helper Hints first, answers after you try

Stuck on this one? Ask for a hint and I’ll point you in the right direction, without giving the answer away. Once you’ve checked your answer, I’ll show you how the marks are awarded.