Level:
Correct: 0
Incorrect: 0
Marks: 0/0
Exam Practice
Course:
Topics:
OCR GCSE Biology (Paper 2) Smart practice A mixed round aimed at your weak spots
Avg
score:
–
Topics
done:
0/28

Aseptic techniques

Practise 10 exam-style questions on Aseptic techniques for OCR GCSE Biology (Paper 2). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 10 questions
  • 1–4 marks each
  • Instant marking
  • No sign-up needed
10 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

1 mark

A student heats a wire inoculating loop in a Bunsen burner flame until it glows red. She then waits a few seconds before she dips the loop into a culture of bacteria.

Why does she wait?

Choose your answer.

  • A So that a hot loop does not kill the bacteria it picks up
  • B So that bacteria from the air can settle on the loop
  • C So that the bacteria on the loop can reproduce
  • D So that the loop has enough time to become completely sterile

Model answer

A

Explanation

Heating the loop until it glows red kills any microorganisms on it, so the loop is sterile. But a very hot loop would also kill the bacteria the student wants to transfer, so she lets it cool for a few seconds first, holding it near the flame and not putting it down.

Mark scheme
  1. 1 mark

    A / So that a hot loop does not kill the bacteria it picks up

    The only correct answer is A: a red-hot loop would kill the bacteria it touches, so the loop must cool before it is dipped into the culture. B is not correct because bacteria from the air would contaminate the culture; nothing should be allowed to settle on the loop. C is not correct because the student wants to transfer the bacteria, not grow them on the loop, and there is no time for them to reproduce. D is not correct because heating the loop until it glows red is what makes it sterile; waiting does not make it more sterile. ALLOW the letter or the option. If more than one option is given, do not award the mark.

Question 2

1 mark

A school buys plastic Petri dishes for growing bacteria. The dishes come in sealed packs labelled 'sterile'.

What does 'sterile' mean?

Model answer

Sterile means that there are no living microorganisms on or in the dishes: all of them, including spores, have been killed.

Explanation

Something sterile has no living microorganisms at all, not just fewer of them. Growth media and equipment must be sterile before a culture is started, so that the only microorganism that grows is the one being studied. A dish can look clean and still not be sterile.

Mark scheme
  1. 1 mark

    there are no (living) microorganisms on / in it / all microorganisms (and their spores) have been killed

    ALLOW no living bacteria, fungi or viruses / no living cells / free from microorganisms. ALLOW no germs. IGNORE clean / hygienic / no dirt. DO NOT ALLOW 'has fewer microorganisms' / 'most microorganisms have been killed'.

Question 3

2 marks

A technician makes nutrient agar in glass flasks. She covers the neck of each flask with aluminium foil and then heats the flasks in an autoclave. She leaves the foil on the flasks until the agar is poured into Petri dishes.

Explain why the technician autoclaves the flasks of agar and why she leaves the foil on until the agar is poured.

Model answer

The autoclave kills all the microorganisms, including spores, in the agar and the flask, so the agar is sterile. The foil cover stops microorganisms from the air falling into the flask while the agar cools and waits to be used, so the agar stays sterile until it is poured.

Explanation

Sterilising the agar is no use if microorganisms can get back in afterwards. Covering the opening before autoclaving means the agar is never open to the air until the moment it is poured, which is one of the measures that stop contaminants falling into growth media.

Mark scheme
  1. 1 mark

    the autoclave kills all (the) microorganisms (and spores) in the agar / flask, so the agar is sterile

    ALLOW sterilises the agar and the flask. ALLOW so that only the microorganism being studied will grow on the agar. IGNORE 'cleans the agar' / 'melts the agar'.

  2. 1 mark

    the foil stops microorganisms from the air / dust getting into the flask / falling onto the agar after it has been sterilised (while it cools or is stored), so the agar stays sterile

    ALLOW the foil stops the agar being contaminated (again) before it is used. IGNORE the foil keeps the agar warm.

Question 4

3 marks

A student grew a culture of yeast in a flask of sterile nutrient broth. She looked at a drop of the culture with a light microscope.

She saw many yeast cells. Each yeast cell was about 8 μm across and had a nucleus. She also saw some rod-shaped cells, each about 2 μm long, with no nucleus.

Name the type of organism that the rod-shaped cells are most likely to be, and give one reason for your answer.

Suggest one way that these cells could have got into the culture.

Model answer

The rod-shaped cells are bacteria, because they have no nucleus and they are much smaller than the yeast cells.
They could have got in from the inoculating loop if it was not flamed properly before it was used.

Explanation

Yeast is a fungus, so its cells are eukaryotic and have a nucleus. Bacteria are prokaryotic: their genetic material is not in a nucleus, and they are usually much smaller, only a few micrometres long. Bacteria in a yeast culture mean the culture has been contaminated, so one of the aseptic steps failed.

Mark scheme
  1. 1 mark

    bacteria / bacterium

    ALLOW prokaryotes / prokaryotic cells. DO NOT ALLOW virus / fungus / yeast / protist.

  2. 1 mark

    they have no nucleus / their genetic material is not in a nucleus / they are much smaller than the yeast cells (about 2 μm)

    ALLOW they are prokaryotic cells, which have no nucleus. IGNORE they are rod-shaped on its own. If more than one reason is given, a wrong one cancels a right one.

  3. 1 mark

    the loop / pipette / equipment was not sterilised (flamed) properly

    1 mark for any one of points 3 to 7, max 1. If more than one answer is given, a wrong one cancels a right one.

  4. 1 mark

    the neck of the flask was not flamed / the flask was left open / the bung or cap was put down on the bench

    ALLOW the flask was open for too long.

  5. 1 mark

    the broth / flask was not sterilised properly / was not autoclaved for long enough

    ALLOW the broth was not autoclaved.

  6. 1 mark

    bacteria from the air / from the student's breath, hands or hair fell into the flask when it was open

    ALLOW the student breathed / coughed / talked over the open flask.

  7. 1 mark

    the yeast used to start the culture was already contaminated

    ALLOW the starter culture was not a pure culture.

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Study Helper Hints first, answers after you try