The national grid and transformers

Practise 16 exam-style questions on The national grid and transformers for OCR GCSE Physics (Paper 2). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 16 questions
  • 1–6 marks each
  • Instant marking
  • No sign-up needed
16 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

1 mark

The battery charger for a cordless drill contains a transformer that is 100% efficient.

• potential difference across primary coil = 230 V
• current in primary coil = 0.40 A
• potential difference across secondary coil = 23 V

Use the equation:
potential difference across primary coil × current in primary coil = potential difference across secondary coil × current in secondary coil

What is the current in the secondary coil?

Choose your answer.

  • A 0.040 A
  • B 0.40 A
  • C 4.0 A
  • D 92 A

Model answer

C (4.0 A)

Explanation

Substitute into the equation: 230 × 0.40 = 23 × current in secondary coil, so the current in the secondary coil = 92 ÷ 23 = 4.0 A. This is a step-down transformer, so the current in the secondary coil is larger than the current in the primary coil.

Mark scheme
  1. 1 mark

    C / 4.0 A

    The only correct answer is C: 230 × 0.40 = 23 × current in secondary coil, so current = 92 ÷ 23 = 4.0 A. A is not correct because it comes from 23 × 0.40 ÷ 230 (the two potential differences swapped). B is not correct because the current is not the same in both coils when the potential difference changes. D is not correct because 92 (230 × 0.40) is the power input in watts; it must still be divided by 23 V. ALLOW the letter or the option. If more than one option is given, do not award the mark.

Question 2

2 marks

A desk lamp contains a transformer that is 100% efficient.

• potential difference across primary coil = 230 V
• current in primary coil = 0.25 A
• current in secondary coil = 4.8 A

Use the equation:
potential difference across primary coil × current in primary coil = potential difference across secondary coil × current in secondary coil

Show that the potential difference across the secondary coil is about 12 V.

Model answer

230 × 0.25 = potential difference across secondary coil × 4.8
potential difference across secondary coil = 57.5 ÷ 4.8 = 11.98 V, which is about 12 V

Explanation

Multiply the primary values first: 230 × 0.25 = 57.5, which is the power in watts. The same power leaves the secondary coil, so divide by the secondary current: 57.5 ÷ 4.8 = 11.98 V. In a 'show that' question you must give your answer to more figures than the value printed, or you have not shown anything.

Mark scheme
  1. 1 mark

    substitution: 230 × 0.25 = potential difference across secondary coil × 4.8 / potential difference across secondary coil = 230 × 0.25 ÷ 4.8 / 57.5 ÷ 4.8

    This is a 'show that' question: the marks are for the working, and the given value (12 V) on its own scores 0. DO NOT ALLOW working that uses 12 V to get back to one of the given values (for example 12 × 4.8 ÷ 230) unless the potential difference across the secondary coil is also calculated from the given values.

  2. 1 mark

    evaluation: 11.98 (V) / 11.979 (V) / 12.0 (V)

    Dependent on point 1. The value must be given to at least 3 significant figures (more figures than the 12 V in the question). ALLOW 11.97 (V) (truncated).

Question 3

2 marks

On cold winter days in 2024, much more electrical power was used in the UK at 5:30 pm than at 3:00 am. The potential difference of the national grid's transmission cables is the same at both times.

Explain why energy is wasted heating the transmission cables at a much greater rate at 5:30 pm.

Model answer

At 5:30 pm much more power is transferred through the cables. Power = potential difference × current, and the potential difference is the same, so the current in the cables must be larger. The cables have resistance, so a larger current heats them more, and energy is wasted at a greater rate.

Explanation

The national grid keeps the potential difference the same, so when more power is needed, the current has to increase. The heating of a cable depends on the current (power wasted = (current)² × resistance), so the energy wasted rises sharply when demand is high. This is why the grid uses a very high potential difference: it keeps the current, and so the heating, as small as possible.

Mark scheme
  1. 1 mark

    more power is transferred, so (because power = potential difference × current and the potential difference is the same) the current in the cables is larger at 5:30 pm

    The idea of a larger current is needed for this mark. ALLOW at the same potential difference, more power needs a larger current. IGNORE more electricity is used (on its own: this repeats the question). DO NOT ALLOW the potential difference is higher at 5:30 pm.

  2. 1 mark

    a larger current heats the cables more (because they have resistance), so energy is dissipated at a greater rate

    ALLOW power wasted = (current)² × resistance, so a larger current wastes more power. ALLOW the heating effect of a current increases as the current increases. IGNORE it is colder in winter (the question is about the energy wasted, not the temperature outside).

Question 4

4 marks

An arc welder joins pieces of steel. A very large current passes through a metal rod and the steel, and the heating effect of the current melts the metal.

The welder contains a transformer that is 100% efficient.

• potential difference across primary coil = 230 V
• current in primary coil = 16 A
• potential difference across secondary coil = 28 V

Use the equation:
potential difference across primary coil × current in primary coil = potential difference across secondary coil × current in secondary coil

Calculate the current in the secondary coil. Give your answer to 2 significant figures.

Explain why the welder uses a step-down transformer.

Model answer

230 × 16 = 28 × current in secondary coil
current in secondary coil = 3680 ÷ 28 = 131.4 A
= 130 A (2 significant figures)
The step-down transformer lowers the potential difference, so the current in the secondary coil becomes much larger (about 130 A instead of 16 A). A very large current is needed to heat the metal enough to melt it.

Explanation

Substitute and rearrange: current in secondary coil = (230 × 16) ÷ 28 = 131.4 A, which is 130 A to 2 significant figures (two figures, then fill with a zero). In a transformer the power stays the same, so stepping the potential difference down makes the current go up: that very large current gives the strong heating effect the welder needs.

Mark scheme
  1. 1 mark

    substitution and rearrangement: 230 × 16 = 28 × current in secondary coil / current in secondary coil = 230 × 16 ÷ 28 / 3680 ÷ 28; or a correct final answer of 130 A (or 131 A or 131.4 A) with no working

    An answer of 130 A with no working scores marking points 1 to 3 only. An answer of 131 A or 131.4 A with no working scores marking points 1 and 2 only (not rounded to 2 significant figures). 1.9 A (28 × 16 ÷ 230, the potential differences swapped) scores 0 for points 1 and 2.

  2. 1 mark

    evaluation: 131.4 (A) / 131 (A); or a correct final answer of 130 A (or 131 A or 131.4 A) with no working

    ALLOW 131.43 (A).

  3. 1 mark

    130 (A) (to 2 significant figures)

    ALLOW ECF for the rounding mark from a wrong answer correctly rounded to 2 significant figures (for example 1.948 A given as 1.9 A).

  4. 1 mark

    the step-down transformer decreases the potential difference, so the current in the secondary coil is much larger than in the primary coil, and a very large current is needed to heat and melt the metal

    ALLOW it gives a (much) larger current (about 130 A instead of 16 A) to make the metal hot enough to melt. ALLOW the lower potential difference is safer for the person welding (as a second idea only if the large current is also given). DO NOT ALLOW the transformer increases the power / makes extra energy.

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.