Level:
Correct: 0
Incorrect: 0
Marks: 0/0
Exam Practice
Course:
Topics:
Avg
score:
–
Topics
done:
0/26

Electrolysis of copper sulfate solution

Practise 17 exam-style questions on Electrolysis of copper sulfate solution for Edexcel GCSE Combined Science (Chemistry Paper 1). Write your answer as you would in the exam and get it marked in seconds against the mark scheme, point by point, with the Study Helper on hand if you get stuck.

  • 17 questions
  • 1–6 marks each
  • Instant marking
  • No sign-up needed
17 questions, marked as you go

Sample questions with model answers

Here are 4 of the questions in this topic, each with a model answer, an explanation of why it earns the marks and the mark scheme an examiner would use.

Question 1

1 mark

Leah uses two inert carbon rods to pass a current through blue copper(II) sulfate solution.

Which half equation describes the change at the positive rod?

Choose your answer.

  • A Cu²⁺ + 2e⁻ → Cu
  • B 4OH⁻ → O₂ + 2H₂O + 4e⁻
  • C Cu → Cu²⁺ + 2e⁻
  • D 2H⁺ + 2e⁻ → H₂

Model answer

B - 4OH⁻ → O₂ + 2H₂O + 4e⁻

Explanation

Oxidation happens at the anode, so the anode half equation has electrons on the right-hand side; with an inert anode it is the hydroxide ions that lose electrons, forming oxygen. Option C is the anode reaction only when the anode is copper, which is why the electrode material matters.

Mark scheme
  1. 1 mark

    B / 4OH⁻ → O₂ + 2H₂O + 4e⁻ (1)

    The only correct answer is B: at an inert (graphite) anode, hydroxide ions lose electrons to form oxygen. A is not correct because this is the reaction at the cathode (reduction); C is not correct because this happens only when the anode is made of copper - a graphite anode contains no copper atoms; D is not correct because it is a cathode reaction, and copper, not hydrogen, forms at the cathode in copper sulfate solution. Accept the letter or the option. If more than one option is given, do not award the mark.

Question 2

2 marks

Jamal passes different currents through copper sulfate solution between copper electrodes. He measures how much the mass of the cathode increases each time.

The independent variable is the current.

Give two variables that Jamal should control.

Model answer

The student should keep the time for which the current flows the same, and use the same concentration of copper sulfate solution in every experiment. (The volume of solution, distance between the electrodes, size of the electrodes and temperature should also be kept the same.)

Explanation

Control variables are everything except the independent variable (current) and the dependent variable (increase in mass) that could affect the result. Time is the most important, because the mass deposited depends on both the current and how long it flows. Voltage is not a control variable here, because it must change for the current to change.

Mark scheme
  1. 1 mark

    time (for which the current flows) (1)

    Any two from the six points; max 2. Accept 'how long the electrolysis lasts'.

  2. 1 mark

    concentration of the copper sulfate solution (1)

    Accept 'same copper sulfate solution'. Ignore 'amount of copper sulfate' unless concentration is meant.

  3. 1 mark

    volume of copper sulfate solution (1)

    Accept 'depth of solution'.

  4. 1 mark

    distance between the electrodes (1)

    Accept 'how far apart the electrodes are'.

  5. 1 mark

    size / surface area of the electrodes (in the solution) (1)

    Accept 'how far the electrodes are dipped into the solution'. Ignore 'same electrodes' / 'type of electrode' (both are copper).

  6. 1 mark

    temperature (of the solution) (1)

    Do not accept current (the independent variable), mass of the cathode (the dependent variable) or voltage (it is changed to change the current).

Question 3

3 marks

An impure copper anode contains small amounts of zinc and silver. During the purification of copper:
- the zinc ends up dissolved in the copper sulfate solution as zinc ions
- the silver falls to the bottom of the cell as solid silver in the 'anode sludge'
- only copper is deposited on the cathode.

Zinc is more reactive than copper. Silver is less reactive than copper.

Explain these observations.

Model answer

Zinc is more reactive than copper, so zinc atoms in the anode lose electrons even more easily than copper atoms; they form Zn²⁺ ions and dissolve in the solution. Silver is less reactive than copper, so silver atoms do not lose electrons at the anode; as the copper around them dissolves, the silver is left as a solid and falls to the bottom as anode sludge. At the cathode, copper ions and zinc ions are both attracted, but copper is less reactive than zinc, so only the copper ions gain electrons and are deposited, and the zinc ions stay in solution.

Explanation

The reactivity series shows how readily a metal forms positive ions. At the anode, metals more reactive than copper are oxidised and dissolve, while less reactive metals are not and drop off as sludge. At the cathode the least reactive metal ion present, copper, is reduced, so the cathode copper is pure. Answers must talk about atoms losing electrons at the anode and ions gaining electrons at the cathode.

Mark scheme
  1. 1 mark

    zinc is more reactive than copper, so zinc atoms (also) lose electrons / form ions at the anode and dissolve (1)

    Accept 'zinc is oxidised to Zn2+ ions' / Zn → Zn2+ + 2e-. Accept 'more reactive metals form positive ions more easily'.

  2. 1 mark

    silver is less reactive than copper, so silver atoms do not lose electrons / do not form ions, and they fall off as the copper around them dissolves (1)

    Accept 'silver is not oxidised, so it stays as solid silver'. Do not accept 'silver is insoluble' on its own.

  3. 1 mark

    at the cathode copper ions gain electrons rather than zinc ions, because copper is less reactive than zinc (so zinc ions stay in solution) (1)

    Accept 'copper ions are discharged in preference to zinc ions'. Accept Cu2+ + 2e- → Cu with the reason. Do not accept 'zinc ions are not attracted to the cathode'.

Question 4

4 marks

Copper sulfate solution is electrolysed using copper electrodes. With a current of 0.20 A for 30 minutes, the mass of the cathode increases by 0.118 g.

The mass of copper deposited is directly proportional to the current and directly proportional to the time.

Calculate the increase in mass of the cathode when a current of 0.50 A passes for 45 minutes.

Explain, in terms of electrons and ions, why a larger current deposits more copper on the cathode in the same time.

Model answer

The current is 0.50 ÷ 0.20 = 2.5 times larger and the time is 45 ÷ 30 = 1.5 times longer.
increase in mass = 0.118 × 2.5 × 1.5 = 0.4425 g = 0.44 g
A larger current means that more electrons flow to the cathode every second. Each copper(II) ion gains two electrons to form a copper atom (Cu²⁺ + 2e⁻ → Cu), so more copper ions are reduced and more copper atoms are deposited on the cathode in the same time.

Explanation

Because the mass deposited is proportional to both the current and the time, multiply the original mass by both scale factors (2.5 for the current and 1.5 for the time); using only one factor gives 0.295 g or 0.177 g. The current is the rate of flow of electrons, and every copper atom deposited needs two electrons, so more electrons per second means more Cu²⁺ ions reduced per second. The mass gained comes from copper atoms, not from the electrons themselves.

Mark scheme
  1. 1 mark

    a correct scaling step, e.g. 0.118 × (0.50 ÷ 0.20) × (45 ÷ 30) / 0.118 × 2.5 × 1.5 / 0.118 ÷ (0.20 × 30) × (0.50 × 45) (1)

    0.44 (g) with or without working scores 2 (MP1 and MP2). Award MP1 for one correct scaling seen if the final answer is wrong, e.g. 0.118 × 2.5 = 0.295 (g) (current only) or 0.118 × 1.5 = 0.177 (g) (time only), or 0.118 ÷ 0.20 = 0.59 (g per A in 30 minutes), or 0.118 ÷ 30 = 0.00393 (g per minute at 0.20 A). Ratios inverted (e.g. 0.118 × 0.20 ÷ 0.50) score 0.

  2. 1 mark

    0.44 (g) (1)

    Accept 0.4425 / 0.443 / 0.44, and 0.45 only if it comes from correct rounding of an intermediate value (e.g. 0.020 g per A per minute × 0.50 × 45). Ignore the unit. Do not accept 0.295 or 0.177 (only one factor used) for MP2.

  3. 1 mark

    a larger current means more electrons flow (to the cathode) per second / more charge flows (in the same time) (1)

    An explanation linking. Accept 'a higher rate of electron flow / electron transfer'. Ignore 'electrons move faster' unless linked to more electrons arriving per second. Do not accept 'more electrons are added to the cathode, so it gets heavier' (the mass gained is copper, not electrons).

  4. 1 mark

    so more copper(II) ions gain electrons / are reduced / are discharged and form copper atoms (on the cathode) per second (1)

    Accept Cu2+ + 2e- → Cu with the idea that more ions react in the same time. Accept 'more Cu2+ ions are reduced to copper'. Do not accept 'copper atoms gain electrons' or 'copper ions lose electrons'. Ignore 'more copper forms' with no reference to ions or electrons.

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Study Helper Hints first, answers after you try

Stuck on this one? Ask for a hint and I’ll point you in the right direction, without giving the answer away. Once you’ve checked your answer, I’ll show you how the marks are awarded.