Question 1
1 markIn the plug of an electrical appliance, the fuse is connected in the live wire.
Why is the fuse connected in the live wire and not in the neutral wire?
Choose your answer.
- A only the live wire has a current
- B the neutral wire is at about 230 V
- C the fuse melts faster in the live wire
- D it cuts the device off from 230 V
Model answer
D - when the fuse melts, it cuts the device off from the 230 V live wire.
Explanation
A fuse in the neutral wire would still stop the current when it melted, but the appliance would remain connected to the live wire at 230 V, so touching a faulty part could still give a shock. With the fuse in the live wire, a melted fuse isolates the appliance from the high p.d. The current is the same in the live and neutral wires.
Mark scheme
-
1 mark
D / it cuts the device off from 230 V (1)
The only correct answer is D: when a fuse in the live wire melts, the appliance is disconnected from the live wire, which is at about 230 V, so no part of the appliance is left at a high p.d. A is not correct because the live and neutral wires are in series with the appliance, so the current in them is the same. B is not correct because the neutral wire is at about 0 V; it is the live wire that is at about 230 V. C is not correct because the current is the same in both wires, so a fuse would melt at the same current in either; the reason is what happens after it melts. Accept the letter or the option. If more than one option is given, do not award the mark.