Question 1

1 mark

A laboratory power supply contains a transformer that is 100% efficient.

• potential difference across primary coil = 230 V
• current in primary coil = 0.50 A
• potential difference across secondary coil = 12 V

For this transformer: potential difference across primary coil × current in primary coil = potential difference across secondary coil × current in secondary coil

What is the power output from the secondary coil?

Choose your answer.

  • A 6.0 W
  • B 115 W
  • C 460 W
  • D 2760 W

Model answer

B

Explanation

Each side of the transformer equation is a power (p.d. × current). For a 100% efficient transformer the power output equals the power input, so the output power is 230 V × 0.50 A = 115 W, even though the secondary p.d. is only 12 V. The secondary current is then 115 ÷ 12 = 9.6 A. Mixing a p.d. from one coil with a current from the other is the common slip.

Mark scheme
  1. 1 mark

    B / 115 W

    The only correct answer is B: power = potential difference × current, so the power input = 230 × 0.50 = 115 W, and a transformer that is 100% efficient has a power output equal to its power input (each side of the equation is the power). A is not correct because 12 × 0.50 = 6.0 W multiplies the secondary p.d. by the primary current, which are in different coils. C is not correct because 230 ÷ 0.50 = 460 divides the p.d. by the current instead of multiplying. D is not correct because 230 × 12 = 2760 multiplies the two potential differences, which does not give a power. ALLOW the letter or the option. If more than one option is given, do not award the mark.

Question 2

2 marks

A thicker cable has a lower resistance than a thinner cable made of the same material.

Engineers could reduce the energy wasted in the transmission cables of the national grid by using much thicker cables.

Explain why thicker cables would waste less energy.

Suggest why the national grid transmits electricity at very high potential differences instead of using very thick cables.

Model answer

A thicker cable has a lower resistance, so for the same current there is less heating of the cable and less energy is wasted (power wasted = I² × R).
Very thick cables would be extremely heavy and expensive, and would need much stronger pylons. Increasing the p.d. reduces the current instead, and because the power wasted depends on the current squared, this reduces the energy wasted far more for much less cost.

Explanation

Energy is wasted because the current heats the cables, and the power wasted is (current)² × resistance. Thick cables reduce the resistance, but only in proportion to the extra metal used. Reducing the current with step-up transformers is far more effective, because halving the current quarters the energy wasted, and it avoids the cost and weight of very thick cables.

Mark scheme
  1. 1 mark

    (thicker cables have a) lower resistance, so (for the same current) there is less heating of the cables / less energy is dissipated (as thermal energy)

    ALLOW power wasted = (current)² × resistance, so a smaller resistance means less power wasted. IGNORE 'less resistance so less energy is lost' with no idea of heating or of energy wasted as thermal energy, unless power = (current)² × resistance is quoted.

  2. 1 mark

    (suggestion) very thick cables would be very heavy / expensive (and need much stronger pylons), but a high p.d. makes the current small, which reduces the energy wasted much more

    ALLOW either idea for the mark: very thick cables would be too heavy or too expensive (much more metal); OR raising the p.d. reduces the current, and the power wasted depends on the current squared, so it is a more effective way to reduce the energy wasted. IGNORE 'thick cables are harder to make' with no reason.

Question 3

3 marks

A step-down transformer at a substation connects a 275 kV transmission line to a lower-voltage network. The transformer is 100% efficient.

• potential difference across primary coil = 275 kV
• current in primary coil = 288 A
• current in secondary coil = 600 A

A student calculates the potential difference across the secondary coil like this:

potential difference across secondary coil = 275 × 600 ÷ 288 = 573 kV

Explain how you can tell, without doing a calculation, that the student's answer must be wrong.

Calculate the correct potential difference across the secondary coil in kV.

Use the equation: potential difference across primary coil × current in primary coil = potential difference across secondary coil × current in secondary coil

Model answer

The transformer is a step-down transformer, so the p.d. across its secondary coil must be less than 275 kV. The student's answer, 573 kV, is larger, so it must be wrong.

Vp × Ip = Vs × Is
275 × 288 = Vs × 600
Vs = 79 200 ÷ 600 = 132 kV

Explanation

Use what you know before calculating: a step-down transformer reduces the p.d., and the current rises as the p.d. falls, so the answer must be below 275 kV. The student rearranged the equation the wrong way round, swapping the two currents. Substituting all four quantities into the equation and then dividing by the current in the secondary coil avoids this error.

Mark scheme
  1. 1 mark

    275 × 288 = potential difference across secondary coil × 600 / potential difference across secondary coil = 275 × 288 ÷ 600; or a correct final answer of 132 kV with no working

    An answer of 132 kV with no working scores marking points 1 and 2. ALLOW the working in volts: 275 000 × 288 ÷ 600 = 132 000 V. ALLOW 1 mark for 132 000 (V) given as the final answer (not converted to kV).

  2. 1 mark

    132 (kV)

    The unit is given in the question, so IGNORE a missing unit.

  3. 1 mark

    it is a step-down transformer, so the p.d. across the secondary coil must be smaller than the p.d. across the primary coil, but the student's answer is larger

    ALLOW the current in the secondary coil is larger than the current in the primary coil, so the p.d. across the secondary coil must be smaller (the power is the same in both coils). ALLOW the student's answer would mean the output power is greater than the input power. IGNORE 'the student rearranged the equation wrongly' with no reason that shows the answer is impossible.

Question 4

4 marks

A student uses a model to show how energy is transferred by the national grid. A 6.0 V power supply represents the power station. Two long nichrome wires represent the cables, and a small electric motor represents the homes that use the electricity. The power supply, the two wires and the motor are connected in series.

The current in the circuit is 0.25 A. The potential difference across each nichrome wire is 1.2 V.

Calculate the efficiency of the model at transferring energy from the power supply to the motor.

Model answer

The wires and the motor are in series, so their p.d.s add up to the supply p.d.
P.d. across the motor = 6.0 − 1.2 − 1.2 = 3.6 V
Power supplied = p.d. × current = 6.0 × 0.25 = 1.5 W
Useful power transferred to the motor = 3.6 × 0.25 = 0.90 W
Efficiency = useful output ÷ input = 0.90 ÷ 1.5 = 0.60 (60 %)

Explanation

In a series circuit the supply p.d. is shared between the components, so the motor has 6.0 − 1.2 − 1.2 = 3.6 V across it: remember that there are two wires. Power = p.d. × current gives the power supplied and the power reaching the motor, and efficiency = useful output ÷ input. Because the current is the same everywhere, 3.6 ÷ 6.0 gives the same answer. The 40% wasted heating the thin wires is why the real national grid uses a very high p.d. and a small current.

Mark scheme
  1. 1 mark

    p.d. across the motor = 6.0 − 1.2 − 1.2 = 3.6 (V); or a correct final answer of 0.60 / 60 % with no working

    An answer of 0.60 (or 60 %) with no working scores 4 marks. ALLOW the shorter route 3.6 ÷ 6.0 = 0.60 (the current is the same everywhere in a series circuit) for 4 marks. ALLOW 2 marks for 0.80 / 80 % (only one wire subtracted: 4.8 V across the motor) if the working is shown. ALLOW 2 marks for 0.40 / 40 % (the fraction of the power wasted in the wires) if correct working for the powers is shown.

  2. 1 mark

    recall power = potential difference × current: power supplied = 6.0 × 0.25 = 1.5 (W) and power transferred to the motor = 3.6 × 0.25 = 0.90 (W); or a correct final answer of 0.60 / 60 % with no working

    ALLOW power wasted in the wires = 2.4 × 0.25 = 0.60 W, subtracted from 1.5 W. ALLOW ECF from a wrong p.d. across the motor shown in the working.

  3. 1 mark

    recall efficiency = useful output ÷ input: efficiency = 0.90 ÷ 1.5; or a correct final answer of 0.60 / 60 % with no working

    ALLOW ECF from wrong powers shown in the working. ALLOW the ratio multiplied by 100 to give a percentage.

  4. 1 mark

    0.60 / 60 (%)

    ALLOW 0.6. IGNORE units unless the question asks for them.

Ready to try the rest? Every answer you write is marked against the mark scheme, so you can see exactly where the marks are.

Study Helper Hints first, answers after you try

Stuck on this one? Ask for a hint and I’ll point you in the right direction, without giving the answer away. Once you’ve checked your answer, I’ll show you how the marks are awarded.